Plate centrifuges should be maintained and repaired frequently

The solid phase impurities in the liquid are separated by the plate centrifuge to achieve the effect of clarification. For the separation of various difficult to separate suspensions. It is especially suitable for solid-liquid separation with low concentration and high viscosity, fine solid phase particles and small solid-liquid weight. The solid phase should be taken out after shutdown. Plate centrifuges are widely used, so the stability and applicability of plate centrifuges are very important.
Common incidents of plate centrifuges:
Because of the high frequency of plate centrifuges, which can damage the machine, the frequency of incidents is also high. The primary reason is due to the improper operation of the experimenter. A common problem is the inability to open the lid and remove the centrifuge tube. When the flat centrifuge button does not work, the more serious problem is that the shaft is not uniformly stressed, resulting in bending, the motor is burned out, and the horizontal bucket is thrown away. lead to more serious incidents and even casualties.
What maintenance should the plate centrifuge pay attention to?
After each use, the centrifuge lid should be opened to allow natural evaporation of heat or moisture. If cryogenic centrifugation has been used, it may freeze. Assuming the ice melts, scrub with a dry cotton gauze. When there is no visible water vapor, close the lid. Assuming the centrifuge rotors can be replaced, each rotor should be removed after use, cleaned with a clean dry medical gauze and placed under the buckle. Do not use sharp scrapers. Aluminum rotors should be cleaned frequently, and centrifuges should not be frequently protected and repaired. When the operator is disengaged, the power should be turned off. For users who use this product for the first time, please consult those who have used this product before or the instruction manual. Do not use blindly.
Pay attention to frequent inspections:
The plate centrifuge should be inspected on time, including checking whether all nuts, bolts, and gaskets are loose, whether the shield is loose, whether the rotor has cracks and other abnormalities, and whether the connecting parts are loose. Check whether the moving parts are blocked or abnormal, and check whether the connection of each line of the circuit system is reliable. If a problem is found, it is necessary to stop using it immediately and contact the manufacturer.

Mainly engaged in import and export trade of goods and technologies; fruit and vegetable chips equipment, corrugated box equipment, beverage processing and production equipment, hyaluronic acid, sodium hyaluronate, hyaluronic acid stock solution and aqueous solution equipment, food, health food, medical equipment and equipment, fine Equipment for chemical products, raw materials for biopharmaceutical products, and intermediate sodium hyaluronate equipment for biopharmaceutical products.

CONTACT US

West of National Road 104, Linqian Neighborhood Committee, Qufu City, Shandong Province

18660726688

smt6688@126.com

Monday to Friday:10:00AM - 6PM

FOLLOW US

 WeChat

phone station

  • Telephone

    • 18660726688
seo seo